Harbor Freight Tools SUBMERSIBLE DIRTY WATER PUMP 93820 User Manual
Page 9
SKU
93819
For technical questions, please call 1-800-444-3353
PAGE 9
93820
4.
Connect the Union (37) to the Coupler (34). Make sure to hand tighten only.
Over-tightening may cause the Union to crack. Then, connect a
1-1/2” diam-
eter Discharge Pipe to the Union.
NOTE: Make sure the Discharge Pipe is
secured to a solid surface, with appropriate hardware (not included), to ensure
the stability of the Pump.
(See Figure E.)
5.
Install an additional union (not included) or other means of separating the Dis-
charge Pipe just above the floor to facilitate removal of the Pump if necessary.
(See Figure E.)
6.
A check valve (not included) is recommended just above, or in place of, the
Union to prevent the backflow of water after each pump cycle. If a Check Valve
is used, a
1/8” diameter air bleed hole should be drilled through the Discharge
Pipe just above the lower Union (37) to prevent Pump “airlock”. A small spray of
water out of this hole is normal while the Pump is running.
(See Figure E.)
CHECK VALVE
OR
UNION
(NOT INCLUDED)
1-1/2” DIAMETER
DISCHARGE PIPE
(NOT INCLUDED)
1/8” AIR BLEED HOLE
(WATER SPRAY IS NORMAL)
POWER CORD & PLUG
(1)
UNION
(37)
FIGURE E
FLOAT SWITCH
(2)
FLOAT
SWITCH LOCK
COUPLER
(34)