CB1200-I Pellet Insert
A
B
C
D
D. Minimum Opening for Masonry and Zero
Clearance Fireplaces for Built-In Using
Rear Shroud
SIDE
W
A
L
L
MANTEL
D
C
E
A
B
Face Trim
Inches
Millimeters
A
Louvers to combustible
side wall
6
153
B
Insert top to mantel
12
305
C
Top to Face Trim
3
76
D
Hearth Extension - Front
6
153
E
Hearth Extension - Sides
8
203
Inches
Millimeters
A
Rear Width
22
558
B
Depth
15-1/2
393
C
*
Height - Top Vent
25-1/2
647
Height - Rear Vent
22-1/2
571
D
Front Width
29-1/4
743
Figure 9.1
Figure 9.2
C. Minimum Clearances To Combustibles for
Masonry and Zero Clearance Fireplaces
*
The size of your floor protector choice must be
added to this dimension. If using Quadra-Fire floor
protector, Part 811-0730, allow 1-1/2” (38mm).
NOTE: A Quadra-Fire floor protector (Part 811-0730) is
available through your dealer to be used as a floor protector
for the section under the insert body only. Floor protection
to front and sides of insert unit must be supplied in addition
to this part.