beautypg.com

Heatmaster 100 N User Manual

Page 10

background image

9

INSTALLATION

Balanced flue boiler connection type: C

• C13: concentric horizontal connection
• C33: concentric vetical connection
• C53: parallel chimney connection
• C63: concentric vertical connection without terminal (only in

Germany and Luxembourg).

C53

C13

C33

2 m min.

150 min.

120

Maximum length concentric : 6 metres
Maximum length parallel : 12 metres

Note: a 90 degree bend = 1 metre equivalent length

A condensation drain outlet must be fitted close to the boiler to prevent condensation products from
the chimney running into the boiler.

To avoid condensation water running out of the terminal, all horizontal flue runs must fall back
towards the boiler.

This manual is related to the following products: