Spark arrester maintenance – HONDA EU 1000i User Manual
Page 50

48
SPARK ARRESTER MAINTENANCE
5 mm SCREWS
MUFFLER GASKET
SPARK ARRESTER
MUFFLER
6 mm BOLTS
MUFFLER PROTECTOR
Clean the spark arrester as follows:
If the generator has been running, the muffler will be very hot. Allow it
to cool before proceeding.
The spark arrester must be serviced every 100 hours to maintain its
efficiency.
Remove the four 5 mm screws, and remove the muffler protector.
Remove the three 6 mm bolts, and remove the muffler, the spark
arrester, and the muffler gasket.
1.
2.