Km-320mwh – Hoshizaki KM-320MAH User Manual
Page 27

27
2. KM-320MWH
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold
should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
PERFORMANCE DATA NO. 05A014
ISSUED: 11/29/05
ITEM: HOSHIZAKI MODULAR CRESCENT CUBER
MODEL: KM-320MWH
70/21
352
160
348
158
324
147
80/27
349
158
342
155
309
140
90/32
348
158
337
153
308
140
lbs./day kg./day
100/38
337
153
330
150
281
127
70/21
80/27
90/32
watts
100/38
70/21
430
1.63
476
1.80
682
2.58
80/27
465
1.76
535
2.03
822
3.11
90/32
476
1.80
585
2.21
842
3.19
gal./day m
3
/day
100/38
605
2.29
645
2.44
1078
4.08
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
263
18.5
263
18.5
265
18.6
80/27
263
18.5
263
18.5
265
18.7
90/32
263
18.5
263
18.5
265
18.6
PSIG kg/cm
2
G
100/38
264
18.6
263
18.5
267
18.8
70/21
53
3.7
54
3.8
55
3.9
80/27
54
3.8
56
3.9
56
3.9
90/32
54
3.8
57
4.0
58
4.0
PSIG kg/cm
2
G
100/38
54
3.8
57
4.0
58
4.1
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
45 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in
bold
should be used for reference only.
We reserve the right to make changes in
specifications and design without prior notice.
28
28
30
2.8
5.0
3.6
4.4
3.5
2.8
4.5
27
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
115-120/60/1
50/10
70/21
90/32
726
727
723
720
719
730
728
727
30
32
33
35
722
718
715
710
31
28
29
31
HARVEST CYCLE TIME
HEAD PRESSURE
4.0
3.4
4.4
2.6
BLSprunger
11/29/2005
2.4
TOTAL HEAT OF REJECTION FROM CONDENSER
5,700 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
APPROVED
CHECKED
WRITTEN
SUCTION PRESSURE
ENG.F-011.1.0205