beautypg.com

3selecting a location for the unit – Herrmidifier Co 707U-UK User Manual

Page 4

background image

3

Selecting a location for the unit

Mounting on face of vertical return duct or side of
horizontal return duct

When mounting your humidifier on the face of a horizontal
return duct, or on the face of a vertical return duct, certain
conditions must be met for its proper operation:

• Mount the humidifier on the vertical or horizontal cold air

return duct.

• Locate the humidifier at least four (4) linear feet upstream of

either the furnace fan and /or filter and any turn in the duct.
This will ensure that condensation does not collect within the
duct and cause oxidation (rust).

• Mount the humidifier at least six (6) linear feet (preferably 10

feet) upstream from any electronic air cleaner. Failure to
follow this recommendation can cause excessive nuisance
arcing and or power supply failure.

• If the duct seams inside the duct are not flat, locate the

humidifier at least three (3) linear feet upstream from the
seam.

• If the humidification needs of the home require more than

one humidifier, each unit should be installed a minimum of (3)
linear feet apart.

• DO NOT use this humidifier on the discharge or warm air

supply side of a forced air heating system. This will reduce the
efficiency of the humidifier and may cause operational
problems.

• DO NOT mount the humidifier in a furnace jacket.

• DO NOT install the humidifier where freezing conditions could

occur.

• DO NOT install on gravity hot air systems.