Henny Penny 520 User Manual
Page 3
Henny Penny
Model 520
7-3. USAGE REVIEW
1. Push PROGRAM button (G) 2 seconds, until “USAGE”
OPERATION
LED (P) flashes. First product is selected.
2. Left display shows usage type for selected product. Type is
“daily” or “total”. Right display shows usage for selected
product. Push PROGRAM button to change between daily
and total displays.
3. If timer alarms occur during usage review, push TIMER button
(B) to acknowledge alarm. Usage review resumes.
4. Push change buttons (C) to select products. When all pro-
duct LEDs (D) turn on, total usage of all products is shown.
5. Push and hold PROGRAM button to exit usage review.
7-4. USAGE REVIEW/
1. While in usage review, press and hold INTERVAL
RESET OPERATION
SELECT button (S) for 5 seconds; the buzzer beeps three
times and the “USAGE RESET” LED will flash.
2. Select product and product type as described above. Push
RESET button (R) to clear displayed usage count.
3. Push and hold PROGRAM button to exit usage review.
7-5. PROGRAMMING IN
1. The two programming levels are: regular program mode and
GENERAL
special program mode. To enter regular program mode, turn
the key switch to the “Program” position, except during a cook
cycle. To enter special program mode, hold the PROGRAM
button (G) for 10 seconds, while in regular program mode.
2. The left display always describes the item being programmed,
and the right display always shows the item setting. Push the
change buttons, (L & R)-4 product controls; (J)-10 product
controls, to change the item shown in the right display. Push
and hold the change button to change the item more quickly.
3. If timer alarms occur while programming, push the TIMER
button (B) to acknowledge the alarm and resume programming.
4. Turn the key switch back to the “Cook” position when done
programming.
600