12

Press and hold down

,

, and

, simultaneously until the screen shows.

You now can change any of these settings.

System Type (Feature Number 4)

System type options are:
1 = Gravity or steam system.
3 = Hot water, high efficiency furnace (90% or better), or single stage heat pump.
6 = Gas or oil forced air furnace (preset).
9 = Electric furnace.

To change your system type:

Press

until display shows your furnace or boiler type.

Press Time

to move to next feature or

to return to main display.

Smart Response™ Technology (Feature Number 13)

Smart Response technology options are:
0 = Smart Response technology on (preset).
1 = Smart Response technology off.

To turn Smart Response technology on or off:

Press

once.

Press Time

to move to next feature or

to return to main display.

NOTE:

See Smart Response technology (page 21) for information about this feature.

Temperature Format (Feature Number 14)

Temperature format options are:
0 = °F (preset).
1 = °C.

To change temperature format:

Press

once.

Press Time

to move to next feature or

to return to main display.

M18750

FEATURE
NUMBER

OPTION

Run

Program

M18751

Run

Program

M18752

Run

Program