OM-227 978 Page 26
7-8. Troubleshooting Table
Trouble
Remedy
No weld output; wire does not feed; fan
does not run
Secure power cord plug in receptacle (see Section 5-6).
does not run.
Replace building line fuse or reset circuit breaker if open.
Place Power switch in On position (see Section 6-1).
Reset welding power source supplementary protector (see Section 7-2).
No weld output; wire does not feed; fan
motor continues to run.
Thermostat TP1 open (overheating). Allow fan to run with gun trigger switch off; thermostat closes when
unit has cooled (see Section 4-2).
Check Voltage range switch position. Rotate knob until it “clicks” into detent at desired range setting.
Secure gun trigger leads (see Section 5-1).
No weld output; wire feeds.
Connect work clamp to get good metal to metal contact.
Replace contact tip (see Section 7-5).
Check for proper polarity connections (see Section 5-4).
Check thumbscrew securing gun end to feed head adapter and tighten if necessary.
Low weld output.
Connect unit to proper input voltage or check for low line voltage.
Place voltage switch in desired position (see Section 6-1).
Electrode wire feeding stops during
welding
Straighten gun cable and/or replace damaged parts.
welding.
Adjust drive roll pressure (see Section 5-11).
Change to proper drive roll groove (see Section 7-4).
Readjust hub tension (see Section 5-8).
Replace contact tip if blocked (see Section 7-5).
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 7-4 or Section 7-6).
Replace drive roll or pressure bearing if worn or slipping (see Section 7-4).
Secure gun trigger leads or repair leads (see Section 5-1).
Check and clear any restrictions at drive assembly and liner (see Section 5-11 or Section 7-6).
Gun is not secured to feed head. Check thumbscrew securing gun end to feed head adapter and tighten
if necessary.
Have nearest Factory Authorized Service Agent check drive motor.