OM-227 978 Page 11
SECTION 5 − INSTALLATION
5-1. Installing Welding Gun
804 686-A
1
Drive Assembly
2
MIG Gun
3
Gun Securing Thumbscrew
4
Gun End
Loosen thumbscrew. Insert end
through opening until it bottoms
against drive assembly. Tighten
thumbscrew.
Welding gun must be inserted
completely to prevent leakage of
shielding gas.
5
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
6
Spool Gun/MIG Gun Switch
Place switch in MIG Gun position.
Close door.
Correct
Incorrect
.
Be sure that gun end is tight against drive assembly.
3
Gun Fully Seated
3
Gun Not Seated
Exposed O-rings
will cause shielding
gas leakage.
5
1
3
2
Spool Gun
MIG Gun
6
4
ЙЙЙ
ЙЙЙ
ЙЙЙ
5-2. Installing Work Clamp
1
Nut
2
Work Cable From Unit
3
Work Clamp
4
Screw
5
Work Clamp Tabs
Bend tabs around work cable.
6
Insulating Sleeves
Slide one insulating sleeve over
work cable before connecting to
clamp.
Slide insulating sleeves over
handles.
802 456-A
.
Connection hardware must be tightened with proper tools. Do not just
hand tighten hardware. A loose electrical connection will cause poor
weld performance and excessive heating of the work clamp.
Tools Needed:
7/16 in
7/16 in
1
2
3
4
5
6