Caution, Warning, Fluid type – Harbor Freight Tools PACIFIC HYDROSTAR 1/3 HP Submersible Sump Pump with Vertical Float Switch 68476 User Manual

Page 4: Power supply

background image

Page 2

For technical questions, please call 1-800-444-3353.

Sump Pump manual

Before start-up, note the following:

The pump can be connected to any shock-proof plug

which has been installed according to regulations.

The plug must have a supply voltage of 120 V~ at 60 Hz.

CAUTION

This pump has been evaluated for use with water only.

WARNING

IMPORTANT! For your own safety –

before starting to run the pump, please have

the following items checked by an expert:

1. Risk of electric shock – This pump is supplied

with a grounding conductor and grounding-type

attachment plug. To reduce the risk of

electric shock, connect only to a properly

grounded, grounding-type receptacle.

2. Risk of electric shock – This pump has not been

investigated for use in swimming pool areas.

3. The electrical connections must be

protected from moisture.

4. If there is danger of flooding, the electrical

connections must be taken to higher ground.

5. Circulation of caustic fluids, as well as the circulation

of abrasive materials, must be avoided at all costs.

6. The pump must be protected from frost.

7. The pump must be protected from running dry.

8. Access by children should also be

prevented with appropriate measures.

9. Position the Pump on a flat, level, solid surface.

Also secure the discharge pipe (not included) to a

solid surface to ensure the stability of the Pump.

10. Do not use with an extension cord.

If a GFCI-protected outlet is not close enough

to the pump, contact a licensed electrician to

install a new one. All wiring must be performed

by a licensed electrician and comply with

the National Electric Code. Do not remove

the round grounding pin from the plug.

11. Turn off power to all circuits before walking on

a wet floor. If you cannot turn power off first,

contact an electrician to turn off the power.

12. Install a backup pump and/or high water alarm

as an additional safeguard against flooding.

13. WARNING: Handling the Power Cord

on this product will expose you to lead,

a chemical known to the State of California

to cause cancer, and birth defects or other

reproductive harm. Wash hands after handling.

(California Health & Safety Code § 25249.5, et seq.)

14. The warnings, precautions, and instructions

discussed in this instruction manual cannot

cover all possible conditions and situations

that may occur. It must be understood by the

operator that common sense and caution are

factors which cannot be built into this product,

but must be supplied by the operator.

Fluid Type

The Pump is designed for use with water with

a maximum temperature of 77° F (25°C).

Do not use the pump for other fluids, especially not

fuels, cleaning fluids, or other chemical products.

Specifications

See Specifications for your model on included sheet.

Installation

The submersible motor pump must be installed

in a stationary position with either:

a. A fixed pipeline or
b. A flexible hose pipe.

Please note!

1. Do not install the pump by suspending it

unsupported from its delivery pipe or power cords.

The pump must be suspended from the

handle or be placed on the bottom of the shaft.

To ensure that the pump works properly,

keep the bottom of the shaft free from

sludge and dirt of all kinds.

2. If the water level sinks too low, any sludge in the

shaft will dry out and stop the pump from starting.

To help ensure the pump will start as required,

check the pump regularly with start-up tests.

Power Supply

1. The pump is equipped with a shock-

proof plug according to regulations.

The pump is designed to be connected to

120 V~, 60 Hz, Ground Fault Circuit Interrupter

(GFCI) protected safety socket.

2. Make sure that the socket is sufficiently

secured and is in excellent condition.

3. When the plug is inserted into the socket

the pump will be on standby.

4. Connect the Pump Power Cord only through the

Float Switch Cord plug to prevent dry running.