7014-082D

September 1, 2008

R

CB 1200 Pellet Stove

We recommend a minimum of 60 in.
(1524mm) vertical, however above the eave
is preferred.

Both installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) “L” or “PL” Listed pellet venting or
listed double wall pipe and Quadra-Fire out-
side air kit in mobile homes. Single wall pipe
is approved for residential installations only.

C. Vertical

D. Through The Wall & Vertical

Firestop

Flashing

Rain Cap

6 in.

(152mm)

Min.

Non-combustible Hearth Pad

3 in. (76mm)

Min.

Clean-out
Cover

24 in. (610mm)

minimum

Ceiling Support

Class A Chimney
Connector Adapter

Top Vent Kit

Non-Combustible Hearth Pad

Clean-out Cover

Tee

Wall Thimble

Support Bracket
every 60 in. (1524mm)

24 in. (610mm)

Minimum

Rain Cap

Flashing

2 in. (51mm) Minimum

6 in. (152mm)
Minimum

Figure 14.1