7.5. ANALOG SIGNAL FOLLOWERS
Analog signals from each channel’s transducers are available for reading or for sending to another power
supply for ratio (Master/Slave) operation. The signal can be sent to a channel on another power supply
and programmed as a Master for that power supply, allowing the remaining three channels to operate as
slaves. When operating 4 – 20 mA instruments, the followers supply a 0 -10 volt signal.
J5
1
Channel 1 Signal
2
Channel 1 Return
3
Channel 2 Signal
4
Channel 2 Return
5
6
7
8
9
10
11
Channel 3 Signal
12
Channel 3 Return
13
Channel 4 Signal
14
Channe l 4 Return
Analog
Out
(HD DB-15)