6. overload protection, 7. servicing optional spark arrestor, Section 8-7 – Hobart Welding Products CHAMPION ELITE OM-240 438E User Manual
Page 42

.
A complete Parts List is available at wwwHobartWelders.com
OM-240 438 Page 38
8-6. Overload Protection
244 029-A
!
Stop engine. Disconnect
negative (−) battery cable.
1
Fuse F1 (See Section 10-1)
F1 protects the weld excitation
winding from overload. If F1 opens,
weld output stops or is low.
2
Fuse F2 (See Section 10-1)
F2 protects the generator power
excitation winding from overload. If
F2 opens, generator power output
stops or is low.
3
Fuse F6 (See Section 10-1)
F6 protects the engine wiring sys-
tem from overload. If F6 opens,
engine will not crank.
Replace any open fuses. Reinstall
cover before operating.
.
If a fuse opens, it usually indi-
cates a more serious problem
exists. Contact a Factory Au-
thorized Service Agent.
3/8 in.
Tools Needed:
2
1
.
Fuses F1, F2 located on
bracket behind left side
panel.
3
.
Fuse F6 located in
harness behind left
side door.
8-7. Servicing Optional Spark Arrestor
244 029-A / Ref. 801 682-A
!
Stop engine and let cool.
1
Spark Arrestor Screen
Clean and inspect screen. Replace
spark arrestor if screen wires are
broken or missing.
1/4 in.
1
Tools Needed: