9 returns, Important, Figure 2 ps series chiller specifications – HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 User Manual
Page 10
Page 10
PS QuarterHorse Series Chillers
1-9 Returns
Important!
Do not return any damaged or incorrect items until
you receive shipping instructions from Application Engineering.
Figure 1
PS025 Process Pump Curve
60 HERTZ PUMP CURVE
CURVES REPRESENT PUMP DISCHARGE ADJUSTED FOR INTERNAL BY-P ASS
PS
025 - PROCES S PUMP S SELECTION
PER MINUTE
LITRES
PER MINUTE
U. S. GALLONS
24
12
18
40
35
80
49
37
52
120
69
160
MTRS
TOTAL HEAD
PSI
FEET
1.5
0.4
3.0
0.8
4.5
1.2
6.1
1.6
7.6
2.0
9.1
2.4
10.6
2.8
3.2
12.1
3.6
13.6
15.1
4.0
4.4
16.7
4.8
18.2
Do not extrapolate pump curves.
Figure 2
PS Series Chiller Specifications
PS
Quarter-
Horse
Series
Cap. @
65°F lwt,
90°F
ambient
Nominal
chilled
water
Compressor
Process
connection
Amp
draw
230/1/60
Dimensions
inches
Oper.
weight
Ship.
weight
PS-025
BTUH
gpm
hp
Pump
inches NPT running L
W
H
lbs.
lbs.
American
standards
2,213
2
¼
1
/
3
hp,
2 gpm @
50 psig
½
6.7 A
20 26 34
100
100
PS
Quarter-
Horse
Series
Cap. @
18°C lwt,
24°C
ambient
Nominal
chilled
water
Compressor
Process
connection
Amp
draw
230/1/60
Dimensions
cm
Oper.
weight
Ship.
weight
PS-025
watts
lpm
watts
Pump
inches NPT running L
W
H
kg
kg
Metric
standards
64.8
7.6
187
224 watts,
7.6 lpm @
345 kPa
½
6.7 A
48 32 66
46
46