Model CW-216/CW-114
PROBLEM
CAUSE
CORRECTION
HEATING SECTION
A. Water will
not heat
B. Water will not
reach desired
temperature
• Replace contactor per Contactor Section
• Check thermostat per Thermostat Section
• Check high limit switch per
High Limit Switch Section
• Faulty contactor
• Faulty thermostat
• Faulty high limit switch
• Low or improper voltage
• Faulty water heating element
• Wiring
• Pans are not over water
• Use a meter and check wall
voltage versus data plate
• Check heating elements per Water Pan
Heater Section
• Check for loose connections or
faulty wires and correct or
replace as necessary
• Place pans over water
C. Radiant heat
not working
• Faulty infinite regulator
• Faulty power switch
• Faulty radiant heater
• Replace infinite regulator per
Infinite Switch Section
• Check power switch, per
Power Switch Section
• Check heater per Radiant Heater Section
1-4
803