The status of stack lift – HP 35s Scientific Calculator User Manual
Page 304

B-4
Memory may inadvertently be cleared if the calculator is dropped or if power is
interrupted.
The Status of Stack Lift
The four stack registers are always present, and the stack always has a stack–lift
status. That is to say, the stack lift is always enabled or disabled regarding its
behavior when the next number is placed in the X–register. (Refer to chapter 2, "The
Automatic Memory Stack.")
All functions except those in the following two lists will enable stack lift.
Category
CLEAR ALL
MEMORY CLEAR
(Default)
Angular mode
Unchanged
Degrees
Base mode
Unchanged
Decimal
Contrast setting
Unchanged
Medium
Decimal point
Unchanged
““
Thousand separator
Unchanged
“1,000”
Denominator (/c value)
Unchanged
4095
Display format
Unchanged
FIX 4
Flags
Unchanged
Cleared
Complex mode
Unchanged
xiy
Fraction–display mode
Unchanged
Off
Random–number seed
Unchanged
Zero
Equation pointer
EQN LIST TOP
EQN LIST TOP
Equation list
Cleared
Cleared
FN = label
Null
Null
Program pointer
PRGM TOP
PRGM TOP
Program memory
Cleared
Cleared
Stack lift
Enabled
Enabled
Stack registers
Cleared to zero
Cleared to zero
Variables
Cleared to zero
Cleared to zero
Indirect Variables
Not defined
Not defined
Logic
Unchanged
RPN