Honeywell 7351F User Manual
Page 17
Model
Schedule Options
User
Interface
Application
Power
Method
Feat ures and Functions
Display
Information
Warranty
Replacements
Sensor
Compatibility
Pr
ogram Options
ENERGY
ST
AR
®
Temporar
y Override
Holiday
Conventional
Heat Pump
Modulating
Fan Coil
PT
AC
R
ea
l T
im
e
C
lo
ck
(Automatically
Updates
Daylight
Savings)
Per
manent
Memor
y
Retention
Recover
y Ramps
LonW
orks
®
C
om
m
m
un
ic
at
in
g
Capability
Economizer
Output
M
ul
tip
le
K
ey
pa
d
Lockout Levels
Dehumidification
Contr
ol
Remote Sensing
Display
Size
(V
iewable)
On-Demand
Backlighting
Continuous Backlighting
Si
m
ul
ta
ne
ou
s
D
is
pl
ay
o
f
Room and Set T
emperatur
e
Honeywell
White-Rodgers
Invensys/Rober
tshaw
Carrier/T
otaline
TCS Basys
T7351F2010
365-
Day
Yes
Yes
Yes
Soft
Keys
3 Heat/
3 Cool or
2 Heat/
4 Cool
3 Heat/
2 Cool
No
24 Vac
Yes
Yes Yes
No
Yes
Yes
(4)
Yes
Yes (Indoor,
Outdoor,
Discharge,
Humidity,
Occupancy)
4.2 sq. in. No Yes
No
1 Year
All T7300s
with non-
Q7300H
subbases
All
White-
Rodgers
Thermostats
All Invensys/
Robertshaw
Thermostats
All Carrier/
Totaline
Thermostats
SZ1022,
SZ1024,
SZ1031,
SZ1033,
SZ1035,
SZ1009
T7771A1005,
TR21,
TR21-A
(averaging),
TR22,
TR23,
TR24,
C7772A1012
(flush mount),
C7770A1006
(return airduct),
C7041P2004
(button sensor)
TB8220U1003
7-Day Yes
Yes
(Cumulative)
Yes
Touch-
screen
2 Heat/
2 Cool
3 Heat/
2 Cool
No
24 Vac
or
Battery
Yes
Yes Yes
No
Yes
Yes
(4)
No
Yes
(Indoor or
Outdoor)
10 sq. in. Yes Yes Yes
5 Years
T7300 with
Q7300A2016,
Q7300A2008,
Q7300C2004
and
Q7300C2012
subbase
1F90 series,
1F80 series
9800 series,
9700i series,
300 series
P374-2100,
P374-2200,
P374-2300,
33CS250-01,
33CS220-01,
33CS071-01,
33CSSP2-WC,
33CSSN2-WC
TR21,
TR21-A
(averaging),
C7772A1012
(flush mount),
C7770A1006
(return air duct),
C7041P2004
(button sensor)
TB7220U1012 7-Day Yes
Yes
(Cumulative)
Yes
Soft
Keys
2 Heat/
2 Cool
3 Heat/
2 Cool
No
24 Vac
or
Battery
Yes
Yes Yes
No
Yes
Yes
(4)
No
Yes
(Indoor or
Outdoor)
4 sq. in. Yes Yes Yes
2 Years
T7300 with
Q7300A2016,
Q7300A2008,
Q7300C2004
and
Q7300C2012
subbase
1F90 series,
1F80 series
9800 series,
9700i series,
300 series
P374-2100,
P374-2200,
P374-2300,
33CS250-01,
33CS220-01,
33CS071-01,
33CSSP2-WC,
33CSSN2-WC
TR21,
TR21-A
(averaging),
C7772A1012
(flush mount),
C7770A1006
(return air duct),
C7041P2004
(button sensor)
TB7100A1000
7-Day Yes
Yes
(Cumulative)
Yes
Soft
Keys
1 Heat/
1 Cool
2 Heat/
1 Cool
No
2 or
4-pipe
2 Heat/
1 Cool
24 Vac
or
Battery
Yes
Yes Yes
No
No
Yes
(5)
No
Yes
(Indoor or
Occupancy)
4 sq. in. Yes Yes Yes
2 Years
T8574B2016,
T8575B2007,
T8575C2005,
T8575D2003
IF90-371,
IF96-344,
IF97-371,
IF80-224,
IF80-241,
IF80-261,
IF86-244,
IF87-251,
IF82-261,
IF89-211
97012,
9610,
9700i,
300-224,
300-225,
300-226,
P274-0100,
P274-1100,
P374-0200,
P374-0300
SZ1-61,
SZ1062
TR21,
TR21-A
(averaging),
C7772A1012
(flush mount),
C7770A1006
(return air duct),
C7041P2004
(button sensor)
17