MAINTENANCE

PREPARING FOR USE AFTER STORAGE

The following steps should be taken before using the cultivator
after it has been stored.
 Unfold the handles into the upright position and secure by

tightening handlebar knobs.

Do not allow throttle cable to

become pinched when raising the handlebar.

 Pull the starter cord three or four times to clean lubricant

from the combustion chamber.

 Remove spark plug from the cylinder. Wipe lubricant from

the spark plug and return it to the cylinder.

 Reconnect spark plug wire.
 Follow the steps on pages 8-10 to refuel and restart the

cultivator.

Air Filter:
 Clean the air filter as previously described.
Cultivator Body:
 Clean dirt, grass, and other materials from the entire unit.
 Wipe the tines with lubricant or spray them with silicone

lubricant to prevent rusting.

 Oil the throttle cable and all visible moving parts. Do not

remove the engine cover.

 Order new parts to replace any that are badly worn or bro-

ken.

 Store in an upright position in a clean, dry place. Store with

the handles in the extended position, or loosen handle knobs
and fold handles down. Do not allow throttle cable to become
pinched when lowering the handlebar.

 Properly dispose of any leftover fuel in compliance with

Federal, state. and local laws.

TROUBLEShOOTING

PROBLEM

CAUSE

REMEDy

Engine fails to start.

Engine switch is in the off position.
No fuel in tank.
Spark plug shorted or fouled.
Spark plug is broken (cracked
porcelain or electrodes broken).
Ignition lead wire shorted, broken, or
disconnected from spark plug.
Ignition inoperative.

Move switch to start.
Fill tank.
Replace spark plug.
Replace spark plug.

Replace lead wire or attach to spark
plug.
Contact authorized service center.

Engine hard to start.

Water in gasoline or stale fuel mixture.

Too much lubricant in fuel mixture.
Engine is under or over choked.
Weak spark at spark plug.

Drain entire system and refill with fresh
fuel.
Drain and refill with correct mixture.
Adjust choke as necessary.
Contact authorized service center.

Engine lacks power.

Air filter clogged.

Clean or replace air filter.

Engine overheats.

Insufficient lubricant in fuel mixture.

Mix fuel as described in starting
instructions.