F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use

with a fan (See Figure 12.3):
• The power supply for the appliance must be brought into

a switch box.

• The power can then be supplied from the switch box

to the appliance using a minimum of 14-3 with ground

wire.

• At the switch box connect the black (hot) wire and red

(switch leg) wire to the wall switch as shown.

• At the appliance connect the black (hot), white (neutral)

and green (ground) wires to the junction box as

shown.

• Add a 1/4 in. insulated female connector to the red

(switch leg) wire, route it through the knockout in the face

of the junction box, and connect to the top fan switch

connector (1/4 in. male) as shown.

Red

Switch

Switch Box

Red

Black

Black

Green

Green

White

Power

Supply

Wires

White

R

ed

B

la

ck

G

re

en

W

hi

te

Minimum 14-3 AWG
with Ground

Junction Box

Knockout

Figure 12.3 Junction Box Wired to Wall Switch or BC10

G. Control Module Operation

1. The control module has an ON/OFF/REMOTE selector

switch that must be set. See Figure 12.4.

OFF Position: Appliance will ignore all power inputs and

will not respond to any commands from a wall switch or

remote. The unit should be in the OFF position during

installation, service, battery installation, and in the event

that the control goes into LOCK-OUT mode as a result

of an error code.

ON Position: Appliance will ignite and run continuously

in the HI flame setting, with no adjustment in flame

output. This mode of operation is primarily used for

initial installation or power outage operation with battery

backup.

REMOTE Position: Appliance will initiate commands

from a wired wall switch and/or one of the optional

wireless remote options.

2. A wall switch can be wired into the control module brown

and red wires. See Figure 12.1.

Figure 12.4 Control Module

NG/LP SETTING

STATUS INDICATOR LED

SELECTOR

SWITCH

FLAME HI/LO SWITCH

(RC100 OR WIRED WALL SWITCH ONLY)

3. If using a wired wall switch with the module in REMOTE

mode, the flame output can be adjusted with the HI/LO

selector switch on the module. See Figure 12.4. Note

that the flame HI/LO selector switch will become inactive

once an optional remote control (RC200/RC300) is

programmed to the control module. Note that the control

module will always ignite the fireplace on HI and remain

so for the initial 10 seconds of operation. If the HI/LO

is switched to the LO position, the flame output will

automatically drop to the lowest setting after the flame

has been established for 10 sec. After this 10 second

period, the flame can be adjusted from HI to LO with

the switch.

4. The control module has safety feature that automatically

shuts down the fireplace after 9 hours of continuous

operation without receiving a command from the

remote.

5. If you intend to use both a wired wall switch and an

optional wireless wall switch to operate your fireplace,

the wall switch will override any commands given by

the remote.

6. The module has the capability to recognize potential

malfunctions. If these occur, it will fail to ignite and/or

respond to a command to ignite via the wall switch and/

or remote. In this case, the module may have gone

into LOCK-OUT mode. In this state, it will emit a RED/

GREEN LED error code. To reset the error code, switch

the selector to OFF, and then back to REMOTE or ON.

If the ignition command again fails, the module will emit

an LED error code, prior to going back into LOCK-OUT

mode. Contact your dealer for service if this occurs.

Nine Hour Safety Shutdown Feature

This appliance has a safety feature that automatically

shuts down the fireplace after 9 hours of continuous

operation without receiving a command from the

remote.