II. INSTALLATION AND OPERATING INSTRUCTIONS
1. CHECKS BEFORE INSTALLATION
IMPORTANT
Remove shipping carton, tape(s) and packing. If packing material is left in the
icemaker, it will not work properly.
1) Remove the panels to prevent damage when installing the icemaker. (See “2. HOW TO
REMOVE PANELS.”)
2) Remove the package containing the accessories from the compressor compartment.
3) Remove the protective plastic film from the panels. If the icemaker is exposed to the sun
or to heat, remove the film after the icemaker cools.
4) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan
blade turns freely.
5) Check that the Compressor is snug on all mounting pads.
6) See the Nameplate on the Rear Panel, and check that your voltage supplied corresponds
with the voltage specified on the Nameplate.
7) A remote condenser unit is needed with this model. The recommended remote
condenser unit is HOSHIZAKI CONDENSER UNIT, Model URC-12F.
2. HOW TO REMOVE PANELS - See Fig. 1
a) Front Panel .......... Remove the two screws.
Lift up and pull toward you.
b) Top Panel ............ Remove the two screws, and
then lift off.
c) Side Panel (R) ..... Remove the screw.
Pull slightly toward you, and
take off.
d) Insulation Panel .. Remove the Thumbscrew.
Lift up slightly, and pull toward
you.