III. MAINTENANCE AND CLEANING INSTRUCTIONS

1. CLEANING INSTRUCTIONS

WARNING

1. HOSHIZAKI recommends cleaning this unit at least once a year. More

frequent cleaning, however, may be required in some existing water
conditions.

2. To prevent injury to individuals and damage to the icemaker, do not use

ammonia type cleaners.

3. Always wear liquid-proof gloves for safe handling of the cleaning and

sanitizing solution. This will prevent irritation in case the solution contacts
with skin.

IMPORTANT

1. The Cleaning Valve is used to provide access to the inside of the

Evaporator during the cleaning and sanitizing operation. It should be
closed for all icemaking operation. The Compressor will not operate
unless this valve is completely closed.

2. To open the Cleaning Valve, the Valve Handle should be parallel to the

valve body. To close the valve, the Valve Handle should be at a right angle
to the valve body.

[a] CLEANING PROCEDURE

1) Dilute approximately 27 fl. oz. of recommended cleaner Hoshizaki “Scale Away” or

“LIME-A-WAY” (Economics Laboratory, Inc.), with 5 gal. of water.

2) Remove all ice from the Evaporator and the Storage Bin.