Grounding, Warning – haier PRO XS3 309292L User Manual
Page 12
Installation
12
309292L
Grounding
The following are minimum grounding requirements for
a basic electrostatic system. Your system may include
other equipment or objects which must be grounded.
Check your local electrical code for detailed grounding
instructions. Your system must be connected to a true
earth ground.
•
Pump: ground the pump by connecting a ground
wire and clamp as described in your separate pump
instruction manual.
•
Electrostatic Air Spray Gun: ground the gun by con-
necting the Graco Grounded Air Hose and connect-
ing the air hose ground wire to a true earth ground.
See Check Electrical Grounding, page 13.
•
Air compressors: ground the equipment according
to the manufacturer's recommendations.
•
All air and fluid lines must be properly grounded.
Use only grounded hoses with a maximum of 100
feet (30.5 m) combined hose length to ensure
grounding continuity.
•
All persons entering the spray area: shoes must
have conductive soles, such as leather, or personal
grounding straps must be worn. Do not wear shoes
with non-conductive soles such as rubber or plastic.
If gloves are necessary, wear the conductive gloves
that are supplied with the gun. If non-Graco gloves
are worn, cut off fingers or palm area of gloves to
ensure your hand contacts the grounded gun han-
dle.
•
Object being sprayed: keep the workpiece hangers
clean and grounded at all times. Resistance must
not exceed 1 megohm.
•
The floor of the spray area: must be electrically con-
ductive and grounded. Do not cover the floor with
cardboard or any non-conductive material which
would interrupt grounding continuity.
•
Flammable liquids in the spray area: must be kept in
approved, grounded containers. Do not use plastic
containers. Do not store more than the quantity
needed for one shift.
•
All electrically conductive objects or devices in the
spray area: including fluid containers and wash
cans, must be properly grounded.
WARNING
Fire, Explosion, and Electric Shock Hazard
When operating the electrostatic gun, any
ungrounded objects in the spray area (peo-
ple, containers, tools, etc.) can become
electrically charged. Improper grounding
can result in static sparking, which can
cause a fire, explosion, or electric shock.
Follow the grounding instructions below.
ti1259a