2” Meter and Flow/Pressure Loss Data

Standard Range 1,250 Gal. Min. to 21,250 Gal. Max.

Flow accuracy –– +5% from 3 to 150 GPM

Extended Range 6,250 Gal. Min. to 106,250 Gal. Max.

Dimensions & Flow Data are the same with NT Microprocessor

3” Meter and Flow/Pressure Loss Data

Standard Range 3,750 Gal. Min. to 63,750 Gal. Max.

Flow accuracy –– +5% from 7 to 300 GPM

Extended Range 18,750 Gal. Min. to 318,750 Gal. Max.

Dimensions & Flow Data are the same with NT Microprocessor

Other meters available, consult factory

Where ceiling heights may pose a restriction or a side-mounted configuration is preferred, TNT Series systems are available in this
design configuration. Factory pre-piped and pressure tested, these system designs must be shipped either skid mounted or have
face piping dis-assembled for shipment and re-assembled at the job site. Available with non-corrosive polyglass composite tanks
or steel. Consult factory for details.

2” Meter

3” Meter

Optional skid mounted system
design configurations with or
without factory interconnect-
ing piping for twin or tri-plex
system designs are available, in
both top-mount or side-mount
design configurations.

Skid mounted and
factory pre-piped

2” Brass Meter