Henny Penny BCM-110 User Manual
Page 6

Model BCF-24/65/110, BCM-110
1-3. TROUBLESHOOTING
(Continued)
Problem
Cause
Correction
The evaporator is iced-up
Faulty de-icing heater
Replace de-icing heater
after a De-icing Cycle
Evaporator temperature at end
Increase the setting of step 8, in
of De-icing Cycle too low
Programming Section of
Operator’s Manual
Maximum time of De-icing Cycle
Increase the setting of step 7, in
too short
Programming Section of
Operator’s Manual
Too much water on evaporator
The unit has been shut down without
Start a De-icing Cycle
fins
a De-icing Cycle
Slow to decrease
Compressor not working properly
Check compressor and re-
in temperature (decline in
place if necessary
performance)
Evaporator fan not working properly
Check the fan and replace if
necessary
Temperature of room too high
Ventilate the room
Not enough clearance around unit
Relocate the unit; see Location
Section of the Operator’s
Manual