Henny Penny BCM-110 User Manual
Page 17

Model BCF-24/65/110, BCM-110
2-13. CONDENSATION
2. Bend out the clips securing the rodent cover on the back of
EVAPORATOR (Continued)
the unit, and pull the cover down.
3. Disconnect the wires to the evaporator.
4. Pull up on the bottom of the evaporator to disengage the
evaporator from the bracket. The evaporator is snapped into
place. No hardware is securing it.
5. Replace evaporator in reverse order.
2-14. DOOR SEAL
1. Open door and pull out on a corner of the seal until seal
clears the retainer.
2. Continue around the door, pulling the seal from the door.
3. Install new seal, starting with the four corners first.
603
2-7