beautypg.com

Henny Penny BCM-110 User Manual

Page 16

background image

Model BCF-24/65/110, BCM-110

2-12. FUSE AND FUSE

If the unit has no power, the fuse may be blown. To access the

HOLDER

fuse:

1. Remove the electrical power to the unit.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

2. Remove the two screws securing the front panel and pull

down the panel.

3. Unscrew the fuse cap and pull the 10 amp fuse from the

holder.

To check and replace the fuse holder:

1. Remove the two screws securing the front panel and pull

down the panel.

2. Remove the two bolts securing the control box and pull the

control box from the unit. (See Control Board Section.)

3. Remove the four screws securing box top and remove the top.

4. Remove the wires from the fuse holder and check for conti-

nuity across the terminals. The circuit should show closed.

If open, replace fuse holder.

5. Reinstall the control box and front panel, and unit is now

ready for use.

2-13. CONDENSATION

1. Remove electrical power to unit and allow evaporator to cool.

EVAPORATOR

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

Also, if evaporator is functional, it will be very hot! Allow
evaporator to cool before removing, or burns could result.

2-6

603