beautypg.com

Model ei166r optical, Installation & placement, Technical specification – Ei Electronics Ei166R User Manual

Page 2

background image

Model

Ei166R Optical

Installation & Placement

Wiring for Interconnected Alarms

Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.

Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector

Please consult instruction booklet for specific installation details

Important Precaution:
Do not install the actual smoke/heat alarm
itself in new or renovated buildings until all
work is completed (including floor
coverings) and the building has been fully
cleaned. The wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
smoke chamber and cause problems, and
it will also invalidate the guarantee). If it
must be installed, cover it completely,
particularly around the edges, with a dust
cover (eg. a plastic bag), until all cleaning
is finished.. Connect wires to the unit as in
wiring diagram. All wiring must comply
with local codes.

Technical Specification

Sensor

Optical, uses light scatter from
smoke

Sensitivity:

Complies with BS 5446 Part 1:
2000

Source:

Contains no radioactive material

Airspeed:

Essentially immune to the effect
of airspeed.

Button Test:

Simulates the effect of smoke and
checks chamber, electronics and
horn.

Ambient Light:

Chamber housing design and
compensation overcomes
problems with stray light.

Automatic Self-Test:

Smoke Chamber is tested every 40
Sec. and unit beeps (without LED
flash) if it is degraded.

Insect Screen:

Prevents insects or debris entering
chamber (1.00mm mesh size)

Supply Voltage:

240V AC

Battery back up:

Rechargeable lithium cells

Specifications are subject to change

Power-On Indicator:

Continuous green LED

Alarm:

Electronic Piezoelectric horn

Alarm Sound Output: 85dB (minimum) at 3m

Alarm Status:

Red LED flashes every second on
unit sensing fire

Temperature Range:

0 to 40°C

Humidity Range:

15% to 95% Relative Humidity

Remote Control:

Ei152, Ei159 or MCP400

Interconnect:

Up to 12 interconnected
EI140/141/143/144/145/146/161/1
64/166 smoke or heat alarms,
along with an EI128 relay base

Fixing:

Easi-Fit mounting base

Plastic material:

UL94VO flame retardant

Dimensions:

152mm diameter x 50mm depth

Weight:

385g

Warranty:

5 year (limited) warranty

Approvals:

Kitemarked to BS5446-1:2000, CE
Approved

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Ph.

+353 61 471277

Fx.

+353 61 471053

Email.

[email protected]

www.

eielectronics.com