Removal of the shrouds - insert, Installation of the decorative plates - insert, Installation – Enviro KODIAK 1200 User Manual
Page 38

Figure 50: Changing
decorative plate.
Installation
R
EMOVAL
O
F
T
HE
S
HROUDS
- I
NSERT
:
1. If the surround panel is installed, remove it by lifting the
panel straight up then out.
2. For the right shroud, twist the handle on the air control
clockwise to remove it from the rod.
3. Pull unit forward a few inches, if possible.
4. The shrouds can be removed one of two ways:
a. For the first method, pull the inside edge of the shroud
straight out, approximately 3⁄4” (2cm), in order to unhook
the shroud from unit. Pull the shroud out through the
side.
b. For the second method (recommended for the right
shroud), remove the two (2) T-20 screws that hold the
shroud to the unit (shown in Figure 49). Pull the shroud
out through the side.
5. To install the shroud, follow steps 1 through 4 in reverse
order. Ensure the shrouds are hooked behind both screws on
either side.
Figure 49: Removal of right pod.
I
NSTALLATION
O
F
T
HE
D
ECORATIVE
P
LATES
- I
NSERT
:
1. Remove the shroud from the unit (refer to “R
EMOVAL
O
F
T
HE
S
HROUDS
-
I
NSERT
”)
2. Remove the fan from the left shroud (refer to ”F
AN
R
EMOVAL
- I
NSERT
”)
3. Unfasten the two (2) nuts that secure the plate to the shroud. The nuts
should only be hand-tightened but a
5
/
16
” wrench may be required.
4. Remove the old plate and replace with a new decorative plate.
5. Hand-tighten the two (2) nuts back into place.
6. Re-install the fan into the left shroud.
7. Re-install the shrouds onto the unit.
38