Installation – Enviro KODIAK 1200 User Manual
Page 30
30
Installation
Figure 33: Attaching removable flue.
Figure 34: Leveling leg.
S
URROUND
P
ANEL
S
EALED
I
NSTALLATION
F
OR
USA O
NLY
- I
NSERT
:
Before starting this type of installation
refer to I
NSTALLATION
- M
ASONRY
F
IREPLACE
I
NSTALLATION
- I
NSERT
for additional
information. For clearances refer to
S
PECIFICATIONS
- C
LEARANCES
T
O
C
OMBUSTIBLES
- 1200 I
NSERT
and S
PECIFICATIONS
- C
LEARANCES
T
O
C
OMBUSTIBLES
- 1700 I
NSERT
.
1. Before the face plate is installed
onto the unit, glue a 6” (150mm)
wide R20 fiberglass insulation strip
around the perimeter of the back of
the panels using RTV silicon or stove
gasket cement. When the face plate
is installed onto the unit the insulation
must overlaps the fireplace opening
to form a seal between the masonry
fireplace and the unit’s face plate. Let
the silicon or cement dry.
2. To make the installation of the surround
panel onto the unit easy have the unit
6” (150mm) out from the fireplace,
3. Push the insert into the fireplace,
allowing the insulation to form a seal
between the panels and the fireplace.
Tuck any exposed insulation behind the
face plate.
Figure 35: Installation with Surround Sealed.
Masonry Fireplace
Mantel
Damper Removed
or Fastened Open
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Insulation Around the
Back of the Face Plate
����� �� ��� ���� ���� �� ������������ ��
��������� ���� ������� ���� � �������
��������������� ���� �� �� ��� � ������� ��
��� ������ ����� �� �� �� ��� ������ ���� �����
���� ������� ��� ��� ���� ���������� ����
��� ��� ��������� �� ������� �������������
�������� ������������� ��� ���� ���������
�� ������� ��� �� ��� ������� �� ������ ��������
�� ��������