Masonry fireplace installation - freestanding, Mobile home installation - freestanding, Installation – Enviro KODIAK 1200 User Manual

Page 26

background image

Floor Protection

Combustible Floor

Masonry Fireplace

Rain Cap

Steel Plate or Flashing

Rigid Stainless

Steel Liner

Damper Removed

or Fastened Open

Clean-out tee

Chimney

Support and Clamp

Clean-out

cover

Flexible Stainless

Steel Section

Stainless Steel

Connector Pipe

Listed Liner

Stove pipe must

end higher than liner

Figure 27: Freestanding Installation into existing fireplace.

installer.
Many venting manufacturers

have listed kits available to

connect a stove to a masonry

fireplace. Always follow

the vent manufacturer’s

installation instructions.

The existing damper

may have to be removed

to allow installation.

Installation

M

ASONRY

F

IREPLACE

I

NSTALLATION

- F

REESTANDING

:

Unless you are experienced, we recommend installation by your dealer or a professional

M

OBILE

H

OME

I

NSTALLATION

- F

REESTANDING

:

SPECIAL REQUIREMENTS: Pedestal models 1200 and 1700 are approved for mobile homes. All

freestanding installation requirements in “

Installation Of A Listed, Factory Built Chimney”, must comply

with all local codes that may apply, and the following must be met:
VENTING:
In Canada:
Any ULC-S629 listed chimney system with the accompanying double-wall vent connector.
In U.S.A. Any UL-103-HT listed chimney system with the accompanying double-wall vent connector.

Do not connect a listed chimney of one manufacture with a listed double wall connector from another

manufacture.

26