ASSEMBLY

1) Unpack humidifier from carton and remove all packaging material, wicks, etc.

from box. Remove foam from bottle.

2) Place the humidifier “cabinet” with evaporative wick at the location where the

product will be operated at least 4 inches from the wall. Fill bottle to capacity of
1 ¾ gallons, replace cap and tighten securely. Using both hands to carry the
bottle to the base. NOTE: If only softened water is available, it can be used;
however you will notice a build up of minerals on the evaporative wick much
sooner. Do not spill water on fan motor. Electrical components must be
kept dry.

3) Make sure wick is resting all the way into the
water

channel

as

indicated by the illustrations,

making sure the wick is resting all the way into the

water channel..


700 Wick
Placement

4) Return bottle to its upright position using the handles on

the top of the bottle. Set the bottle in the recessed area,

the top of the bottle flush with the top of the humidifier.

See illustration. When positioned properly, the valve will

open and water will flow into the water channel.

5) We recommend using Essick Air Bacteriostat Treatment

whenever you refill the humidifier reservoir to eliminate

bacterial growth. Add bacteriostat according to the

instructions on the bottle.

6) Plug cord into wall receptacle and turn humidifier on. Note The outlet grille is

louvered and may be rotated 360 degrees to direct the airflow where you want

it.

**When

excessive condensation exists, a lower speed setting is recommended.

CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep
grille dry at all times.

OPERATION & CONTROLS –
1)
The humidifier should be placed at least FOUR inches away from any walls and

away from heat registers. Do not place on soft carpet. Unrestricted airflow into
the unit will result in the best efficiency and performance. Set desired levels
and speed.

2) Model 736 200 only- has an automatic

humidistat. (The humidistat control knob is
located on the right). The humidistat will turn the
humidifier on when the relative humidity in your
home is below the humidistat setting and will turn
the humidifier off when the relative humidity
reaches the humidistat setting. For initial
operation, set the humidistat at its midpoint and
adjust up or down from there to achieve the
desired humidity level.