beautypg.com

Conversions – Summit 43 Inch Island Gas Cooktop Instruction Manual User Manual

Page 11

background image

10

CONVERSIONS

Replacing Nozzles

The burners can be adapted to suit different
types of gas by fitting the nozzles that corres-
pond to the gas used. To do this, it is
necessary to remove the burner heads and
use a straight key "B" to unscrew the nozzle
"A" (see Fig. 7) and replace it with a nozzle
corresponding to the gas used.

Be sure the nozzle is seated tightly.

After making these replacements, the technician must regulate the
burners as described in

Adjustments

on the previous page and reset

any seals. He should affix the label corresponding to the new gas type
to replace the label previously applied. The nozzles and labels may be
included in a kit with the unit, or obtained from the dealer.

How to change the setting of the pressure regulator supplied with the
cooktop:

The gas regulator was set up to Natural Gas. To convert to LP Gas:

1. Unscrew the aluminum cap
2. Remove and turn the plastic pin 180°
3. Screw in the plastic pin
4. Screw in the aluminum cap

To make it easier for the fitter, we have prepared a table indicating the flow
capacities, the heat capacities of the burners, the diameter of the nozzles and
the working pressure for the various types of gas.

Burners

Gas

Normal

Manifold

Pressure,

inches water

column

Injector

Diameter,
1/100 mm

Nominal Heat

Input (Btu/h)

No.

Description

Min.

Max.

1

Ultra-Rapid

Propane HD-5
Natural Gas

11

4

94

170

5100
5100

11000
12000

3

Semi-Rapid

Propane HD-5
Natural Gas

11

4

70

120

2400
2400

6000
6000

1

3

1

3

Arrangement
of Burners

Fig. 7