Technical Specifications

Model

EFI 640

EFI 635

Dimensions (in cm):

Height (cm)

40

40

Width (cm)

59,8

59,8

Depth (cm)

27

27

Maximum absorbed power: 360 W

200 W

Motor absorption:

2 x 140 W

1 x 120 W

Lighting:

2 x 40 W (E14)

2 x 40 W (E14)

Length of the cable:

150 cm

150 cm

Electrical connection:

230 V

230 - 240 V

Subject to change without notice.

Installation

Unpacking

Check that the cooker hood has no damages.

Transportation damages should immediately be

reported to the company responsible for the

transportation.

Damages, faults and eventually missing details

should immediately be reported to the retailer.

Take care of the packing materials so that small

children cannot play with them.

Fitting

The hood is to be mounted on the wall.

When installed, the hood must be not less than 55

cm. above electric burners or 65 cm. above gas or

mixed-fuel burners (Fig. 8).

The hood can be installed above these heights but

for optimum performance it should be installed at

the distance quoted for the appropriate heat source.

Electrical connection for UK

only

WARNING: DOUBLE INSULATED

DO NOT EARTH

Electrical Requirements

Any permanent electrical installation must comply

with the latest I.E.E. Regulations and local Elec-

tricity Board regulations. For your own safety this

should be undertaken by a qualified electrician e.g.

your local Electricity Board, or a contractor who is

on the roll of the National Inspection Council for

Electrical Installation Contracting (NICEIC) or a

suitably competent person.
Electrical Connection

Before connecting to the mains supply ensure that

the mains voltage corresponds to the voltage on the

Min

65 cm

Min

55 cm

Fig. 8

rating plate inside the cooker hood.

This appliance is fitted with a 2 core mains cable

and must be permanently connected to the electric-

ity supply via a double-pole switch having 3mm

minimum contact gap on each pole. A Switched

Fuse Connection Unit to BS1363 Part 4, fitted with

a 5 Amp time delay fuse, is a recommended mains

supply connection accessory to ensure compliance

with the Safety Requirements applicable to fixed

wiring instructions.

This appliance conforms to BS 800: 1988 and EEC

Directive No. 78 308 regarding suppression of

radio and television interference.

Safety warnings for the electrician

The following is valid in Ireland only:

- the wire which is coloured blue must be

connected to the terminal which is marked with

the letter N,

- the wire which is coloured brown must be

connected to the terminal which is marked with

the letter L.