Technical specifications, Installation, Unpacking – Electrolux U30056 EFI 635 User Manual
Page 13: Fitting, Electrical connection for uk only, Fig. 8
13
Technical Specifications
Model
EFI 640
EFI 635
Dimensions (in cm):
Height (cm)
40
40
Width (cm)
59,8
59,8
Depth (cm)
27
27
Maximum absorbed power: 360 W
200 W
Motor absorption:
2 x 140 W
1 x 120 W
Lighting:
2 x 40 W (E14)
2 x 40 W (E14)
Length of the cable:
150 cm
150 cm
Electrical connection:
230 V
230 - 240 V
Subject to change without notice.
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the company responsible for the
transportation.
Damages, faults and eventually missing details
should immediately be reported to the retailer.
Take care of the packing materials so that small
children cannot play with them.
Fitting
The hood is to be mounted on the wall.
When installed, the hood must be not less than 55
cm. above electric burners or 65 cm. above gas or
mixed-fuel burners (Fig. 8).
The hood can be installed above these heights but
for optimum performance it should be installed at
the distance quoted for the appropriate heat source.
Electrical connection for UK
only
WARNING: DOUBLE INSULATED
DO NOT EARTH
Electrical Requirements
Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety this
should be undertaken by a qualified electrician e.g.
your local Electricity Board, or a contractor who is
on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC) or a
suitably competent person.
Electrical Connection
Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on the
Min
65 cm
Min
55 cm
Fig. 8
rating plate inside the cooker hood.
This appliance is fitted with a 2 core mains cable
and must be permanently connected to the electric-
ity supply via a double-pole switch having 3mm
minimum contact gap on each pole. A Switched
Fuse Connection Unit to BS1363 Part 4, fitted with
a 5 Amp time delay fuse, is a recommended mains
supply connection accessory to ensure compliance
with the Safety Requirements applicable to fixed
wiring instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of
radio and television interference.
Safety warnings for the electrician
The following is valid in Ireland only:
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N,
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L.