Model

Ei156TLR Optical

Installation & Placement

Wiring for Interconnected Alarms

Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.

Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector

Please consult instruction booklet for specific installation details

Important Precaution:

Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and
debris from building work can
contaminate the smoke chamber
and cause problems, and it will also
invalidate the guarantee). If it must
be installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Connect wires to the unit as in
wiring diagram. All wiring must
comply with local codes.

Technical Specification

Sensor

Optical, uses light scatter from
smoke


Sensitivity:

Complies with BS 5446 Part 1:
2000


Source:

Contains no radioactive material


Airspeed:

Essentially immune to the effect

of airspeed.


Button Test:

Simulates the effect of smoke and
checks chamber, electronics and
horn.


Ambient Light:

Chamber housing design and
compensation overcomes
problems with stray light.


Automatic Self-Test:

Smoke Chamber is tested every 40

Sec. and unit beeps (without LED

flash) if it is degraded.


Insect Screen:

Prevents insects or debris entering
chamber (1.00mm mesh size)


Supply Voltage:

230V AC


Battery back up:

Rechargeable lithium cells


Power-On Indicator:

Continuous green LED


Alarm:

Electronic Piezoelectric horn


Alarm Sound Output:

85dB (minimum) at 3m


Alarm Status:

Red LED flashes every second on

unit sensing fire


Temperature Range:

0° to 40°C


Humidity Range:

15% to 95% Relative Humidity


Remote Control:

Ei152, Ei159 or MCP400


Interconnect:

Up to 12 interconnected
Ei150/151TLR/154TL/155/156TLH/
156TLR smoke or heat alarms,
along with an EI158 relay base


Fixing:

Screw fixings supplied


Plastic material:

UL94VO flame retardant


Dimensions:

140mm x 120mm x 46mm


Weight:

230g


Warranty:

5 year (limited) warranty


Approvals:

Kitemarked to BS EN 14604:2005,
CE Approved