Manufacturer Command
The purpose of the parameter manufacturer command is to specify the kind of operation requested
in a MANUFACTURER_REQ.
The following manufacturer commands are defined:
1: Assign
PLCI
2:
Advanced Codec control
3: DSP
control
4: Signaling
control
5: RXT
control
6: IDI
control
7: Configuration
control
8: Remove
Codec
9: Options
request
This information element appears in:
Manufacturer Specific
Manufacturer Command Parameters
The purpose of the parameter manufacturer command parameters is to specify command
dependent parameters.
Parameters for manufacturer command 9: Options Request:
dword
Options mask
Manufacturer specific options that have to be enabled:
[Bit 0..5]: reserved, must be set to 0
[Bit 6]: Enable FAX paper formats and resolutions
[Bit 7..31]: reserved, must be set to 0