beautypg.com

Flush mount installation instructions, Figure 7 figure 8 figure 9 – Cafe 24 Inch Built In Microwave Drawer Oven Installation Guide User Manual

Page 6

background image

6

31-7000166 Rev. 0

Flush Mount Installation Instructions

CL

1.

Prepare cabinet opening as shown in Figures 6, 7, 8, and 9 (cont).

Anti-Tip

Block

mounting cleat opening width

Top View

22”

NOTE:

the mounting surface of the finished cleat must sit

1-1/2” back from the face of the cabinet (pushing the face

of the drawer out 1/8”). For ¼”, the cleat must sit 1-3/8”.

Mounting Cleat

Preferred

Electrical

Outlet

Location*

Anti-Tip

Block

24

3

/

16

” min

24

1

/

2

” max

flush opening width

No Oven

22”

mounting cleat opening width

3

/

4

” Shelf

Front View

Front View

Move oven location downward for

extended countertops for better

viewing angle.

Anti-Tip

Block

3

/

4

” Shelf

1

7

/

8

front face of shelf

Front face of

cabinet

16

7

/

8

flush opening

height

Drawer Face

1

/

8

11/2”

Cabinet

Face

Figure 7

Figure 8