beautypg.com

Outside fresh-air connection, Exhaust and fresh air intake locations, Installation – Enviro C-10825 User Manual

Page 16

background image

16

Outside fresh air is mandatory when installing this unit

in airtight homes and mobile homes.

A Fresh-air intake is strongly recommended for all

installations. Failure to install intake air may result in

improper combustion as well as the unit smoking during power

failures.

When connecting to an outside fresh air source, do not use

plastic or combustible pipe. A 15⁄8” minimum (42 mm) ID (inside

diameter) steel, aluminum or copper pipe should be used. It is

recommended, when you are installing a fresh air system, to

keep the number of bends in the pipe to a minimum.

Installation

O

UTSIDE

F

RESH

-A

IR

C

ONNECTION

:

� ��

��� ���

��������

�����

�������

����

Figure 10: Outside Air Connection.

E

XHAUST

A

ND

F

RESH

A

IR

I

NTAKE

L

OCATIONS

:

EXHAUST

Base of unit to center of flue

10

15

/

16

(278 mm)

Center of unit to center of flue

1 3⁄8”

(35 mm)

FRESH AIR INTAKE.

Base of unit to center of intake

8

15

/

16

(227 mm)

Center of unit to center of intake

41⁄8”

(105 mm)

8

15

/

16

"

(227 mm)

4

1

/

8

"

(105 mm

)

1

3

/

8

"

(35 mm)

10

15

/

16

"

(278 mm)

Figure 11: EF5 Inlet and Outlet Location.

This manual is related to the following products: