installation

Connecting to the mains terminal

Warning: This appliance must be

earthed.

We recommend you use a new

length of 6mm

2

twin core and

earthed cable to ensure your

safety.

Make connection as shown by

proceeding as follows:-

Preform wires to the appropriate

shape to suit fitting into the mains

terminal block.

Strip inner insulation on wires using

wirestrippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from

the end of the inner insulation.

Where uninsulated Earth wires are

used ensure they are suitably

sheathed to leave 10mm bare wire

to fit into the terminal.

Clamp bare wires into the relevant

terminal and check they are held

by tugging each one in turn.

Clamp the mains cable securely

ensuring 5mm of the outer

insulation is inside the terminal

block and that the wires are not

taut but not so slack as to cause

any fouling. See diagram.

Place fuse/miniature circuit breaker

in circuit and switch on at mains.

Checking electrical connections

Correct electrical connection can be

confirmed when switching on the

appliance as the timer will be flashing.

Note: House circuit

Earth leakage and continuity tests must

be carried out before the appliance is

connected to the mains supply and re-

checked after fitting.

Connecting to a hob or cooker

point

Either follow in general terms the

instructions for connecting to the

terminal block or refer to the hob

suppliers installation instructions.

Feed the cable through the cabinet

and arrange to route the cable

away from the appliance which

may become hot.