7.2. AC Characteristics

* Unless otherwise specified,

GND

=

0

V

,

V

DD

=

1.8

V

to

5.5

V

,

Ta

=

40

°

C

to

+85

°

C

Item Symbol

Condition

Min.

Typ.

Max.

Unit

SCL clock frequency

f

SCL

400

kHz

Start condition setup time

t

SU;STA

0.6

µ

s

Start condition hold time

t

HD;STA

0.6

µ

s

Data setup time

t

SU;DAT

100

ns

Data hold time

t

HD;DAT

0

ns

Stop condition setup time

t

SU;STO

0.6

µ

s

Bus idle time between
start condition and stop condition

t

BUF

1.3

µ

s

Time when SCL

=

"L"

t

LOW

1.3

µ

s

Time when SCL

=

"H"

t

HIGH

0.6

µ

s

Rise time for SCL and SDA

t

r

0.3

µ

s

Fall time for SCL and SDA

t

f

0.3

µ

s

Allowable spike time on bus

t

SP

50

ns

FOUT duty

t

W

/t

V

DD

=

2.4

V

5.5

V

50% of V

DD

level

45 50 55 %


Timing chart

t

HD ; DAT

t

SU ; DAT

t

HD ; STA

t

LOW

t

HIGH

1 / f

SCL

t

r

t

f

t

SU ; STA

SDA

SCL

START

CONDITION

(S)

BIT 7

MSB

(A7)

BIT 6

(A6)

ACK

(A)

Protocol

t

BUF

t

SU ; STO

STOP

CONDITION

(P)

START

CONDITION

(S)

(P)

(A)

t

HD ; STA

t

SU ; STA

(S)

BIT 0

LSB

(R/W)

(S)

t

SP

Caution: When accessing this device, all communication from transmitting the start condition to transmitting the stop

condition after access should be completed within 0.95 seconds.
If such communication requires 0.95 seconds or longer, the I

2

C bus interface is reset by the internal bus

timeout function.