beautypg.com

For the installer – Electrolux HD 8960 User Manual

Page 4

background image

4

For more detailed information about treatment, recovery and recycling of this product,

please contact your local city office, your household waste disposal service or the

shop where you purchased the product.

For the installer

• When used as an extractor unit, the hood must be fitted with a 120mm diameter

hose.

• When installing the hood, make sure you respect the following minimum

distance from the top edge of the cooking hob/ring surfaces:

electric cookers

500 mm

gas cookers

650 mm

The hood can be installed above these heights but for optimum performance it

should be installed at the distance quoted for the appropriate heat source.

• The national Standard on fuel-burning systems specifies a maximum depression

of 0.04 mbar in such rooms.

• The air outlet must not be connected to chimney flues or combustion gas ducts.

The air outlet must under no circumstances be connected to ventilation ducts for

rooms in which fuel-burning appliances are installed.

• The air outlet installation must comply with the regulations laid down by the

relevant local authorities.

• When the unit is used in its extractor version, a sufficiently large ventilation hole

must be provided, with dimensions that are approximately the same as the outlet

hole.

• National and regional building regulations impose a number of restrictions on

using hoods and fuel-burning appliances connected to a chimney, such as coal or

oil room-heaters and gas fires, in the same room.

• Hoods can only be used safely with appliances connected to a chimney if the

room and/or flat (air/environment combination) is ventilated from outside using a

suitable ventilation hole approximately 500-600 cm

2

large to avoid the possibility

of a depression being created during operation of the hood.

• If you have any doubts, contact the relevant controlling authority or building

inspector’s office.

• Since the rule for rooms with fuel burning appliances is “outlet hole of the same

size as the ventilation hole”, a hole of 500-600 cm

2

, which is to say a larger hole,

could reduce the performance of the extractor hood.

• If the hood is used in its recirculation mode, it will operate simply and safely in the

above conditions without the need for any of the aforementioned measures.

• When the hood is used in its extractor function, the following rules must be

followed to obtain optimal operation:

The ducting must be fire retardent, 120mm in diameter and the length should be

no more than: