beautypg.com

Otp rom – ELAN Home Systems EM78P458 User Manual

Page 7

background image

EM78P458/459

OTP ROM

PWM2

* Defined by PWMCON (IOC51)<6, 7>

VREF 15

I

* External reference voltage for ADC
* Defined by AD-CMPCON (IOCA0)<7>.

CIN-, CIN+,
CO

20, 1,2

I

O

* “-“ -> the input pin of Vin- of the comparator.
* “+”-> the input pin of Vin+ of the comparator.
* Pin CO is the output of the comparator.
* Defined by AD-CMPCON (IOCA0) <5, 6>

TCC 19

I

* Real time clock/counter with Schmitt trigger input pin; it must be tied to
VDD or VSS if it is not in use.

VSS 5

-

Ground.

Table 2 EM78P459 Pin Description

Symbol

Pin No.

Type

Function

VDD

19, 18

-

Power supply.

OSCI 22

I

* XTAL type: Crystal input terminal or external clock input pin.
* RC type: RC oscillator input pin.

OSCO 21

O

* XTAL type: Output terminal for crystal oscillator or external clock input
pin.
* RC type: Clock output with a period of one instruction cycle time, the
prescaler is determined by the CONT register.
* External clock signal input.

P50 14

I

* General-purpose Input only.
* Default value while power-on reset.

P51 ~ P57

15~17
23, 24

1, 2

I/O

* General-purpose I/O pin.
* Default value while power-on reset.

P60 ~ P67

3, 4,

8~13

I/O

* General-purpose I/O pin.
* Default value while power-on reset.

INT

14

I

* External interrupt pin triggered by falling edge.

ADC1~ADC8

3, 4,

8~13

I

* Analog to Digital Converter.
* Defined by AD-CMPCON (IOCA0)<2:4>.

PWM1,
PWM2

15, 16

O

* Pulse width modulation outputs.
* Defined by PWMCON (IOC51)<6, 7>

VREF 17

I

* External reference voltage for ADC
* Defined by AD-CMPCON (IOCA0)<7>.

CIN-, CIN+,
CO

24, 1, 2

I

* ‘-’ -> the Vin- input pins of the comparators.
* ‘+’ -> the Vin+ input pins of the comparators.
* Pin CO is the output of the comparator.
* Defined by AD-CMPCON (IOCA0) <5, 6>

/RESET 20

I

* If it remains at logic low, the device will be reset.
* Wake up from sleep mode when pins status changes.
* Voltage on /RESET/Vpp must not be over Vdd during normal mode.
* Pull-high is on if /RESET is asserted.

TCC 23

I

* Real time clock/counter with Schmitt trigger input pin; it must be tied to
VDD or VSS if it is not in use.

ENTCC

5

I

1: Enable TCC; 0: Disable TCC.

VSS 6,

7

-

Ground.

This specification is subject to change without prior notice. 07.01.2003 (V1.3)

7

This manual is related to the following products: