Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

WARNING: A qualified service person must install

heater. Follow all local codes.

CHECK GAS TYPE

Use only LP-gas. If your gas supply is not LP-gas, do

not install heater. Call dealer where you bought heater

for proper type heater.

THIS INSTALLATION REQUIRES:

Before installing heater, make sure you have the items

listed below:

Piping (check local codes)

Sealant (resistant to LP_Gas)

Equipment shutoff valve*

Ground joint union

Test gauge connection*

Sediment trap

Tee joint

Pipe wrench

*A CSA/AGA certified equipment shutoff valve with 1/8”

NPT tap is an acceptable alternative to test gauge con-

nection. Purchase a CSA/AGA certified equipment shutoff

valve from your dealer.

LOCATING HEATER

This heater is designed to be mounted on the wall. The

heater can also be located on a non-combustible floor,

away from a wall by using the floor mounting stands in-

cluded with the heater. If installed on combustible floor-

ing such as carpeting, tile or other combustible material

other than wood flooring, the heater must be placed on

a wood panel the full width and depth of the appliance.

Figure 4

For convenience and efficiency, install the heater:

Where there is easy access for operation,

inspection, and service.

In the coldest part of the room.

CAUTION: If you install the heater in a home garage:

Heater pilot and burner must be at least 18

inches above floor .

Locate heater where moving vehicle will not hit it.

CAUTION: This heater creates warm air currents. These

currents move heat to wall surfaces next to heater. Install-

ing heater next to vinyl or cloth wall covering or operat-

ing heater where impurities (such as tobacco smoke,

aromatic candles, cleaning fluids, oil or kerosene lamps,

etc.) are present in the air may discolor walls.

WARNING: Never install the heater:
• In a recreational vehicle .

Where curtains, furniture, clothing, or other

flammable objects are less than 36 inches from

the front, top, or sides of the heater.

• As a fireplace insert
• In high-traffic areas
• In windy or drafty areas
WARNING: Heater must be mounted to maintain

the minimum clearances shown in Figure 4. If pos-

sible, provide greater clearances from the floor, ceil-

ing, and joining walls.

FASTENING HEATER TO WALL
Mounting Bracket

The mounting bracket in located on the back panel of

heater (see figure 5). It has been taped there for ship-

ping. Remove mounting bracket from back panel.

Figure 5

Removing Front Panel of Heater

1. Remove three screws on bottom front of front

panel.

2. Pull bottom of front panel forward, then down

(see figure 6)

Attaching Mounting Bracket to Wall

Use holes on each end of mounting bracket to attach

bracket to wall. These holes are 16 inches apart. Attach

mounting bracket to wall in one of two following ways.

Mounting

Bracket

Left

Side

Right

Side

36” min. from

ceiling

6” Min from

adjoining

walls

2” min. to top surface of carpet, tile

or other combustible material

Floor