2. Turn control knob clockwise to the OFF posi-

tion.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1. Turn control knob clockwise to the PILOT/IGN

position.

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern

often.

PILOT FLAME PATTERN

Figure 21 show a correct pilot flame pattern. Figure 22

shows an incorrect pilot flame pattern. The incorrect

pilot flame pattern is not touching thermocouple. This

will cause the thermocouple to cool. When the thermo-

couple cools, the heater will shut down. If pilot flame

pattern is incorrect, as shown in Figure 22:

Turn heater off (see To Turn OFF Gas to Appli-

ance, page 10.

See Troubleshooting, pages 12-13.

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before

servicing.

CAUTION: You must keep control areas, burner and

circulation air passageways of heater clean. Inspect

these areas of heater before use. Have the heater

inspected yearly by a qualified service person. Heater

may need more frequent cleaning due to excess lent

from carpeting, bedding material, pet hair, etc.
Make sure grille guard is in place before running

heater. If screen or grille guard is removed for servicing

it must be replaced prior to operating the heater.

WARNING: Failure to keep the primary air

opening(s) of the burner(s) clean may result in soot-

ing and property damage.

CLEANING ODS/PILOT AND BURNER

Use as vacuum cleaner, pressurized air or

small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit every 2,500

hours of operation or every three months. We also

recommend that you keep the burner tube and pilot

assembly clean and free of dust and dirt. To clean these

parts we recommend using compressed air no greater

than 30 psig.
This can be done by using a vacuum cleaner in the

blow position, using compressed air in a can, please

follow the directions on the can. If you don’t follow

directions on the can you could damage the burner or

pilot assembly. In addition, the directions that follow

should also be followed.

1. Shut off the unit, including the pilot. Allow the

unit to cool for at least thirty minutes.

2. Inspect burner and pilot for dust and dirt.

Figure 17

Note: Your heater may have either pilot assembly.

3. Blow air through the port/slots and holes in the

burner.

A yellow tip on the pilot flame indicates dust and dirt in

the pilot assembly. To clean the pilot assembly find the

small pilot air inlet hole about two inches from where

the pilot flame comes out of the pilot assembly (see

figure 25). With the unit off, lightly blow air through the

air inlet hole. You may blow through a drinking straw if

compressed air is not available.

CLEANING HEATER CABINET

Air passageways

Use a vacuum cleaner or pressurized air to

clean

Figure 25

Exterior

Use a soft cloth dampened with a mild soap

and water mixture. Wipe the cabinet to remove

dust.