Remote Operation, cont’d

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation

4-18

Mute-output settings —

Displays the RGB Delay/Mute/Output-Volume

Adjust window (figure 4-11), which allows you to mute and unmute the
video and audio output for a single output or for all outputs. This
window also displays the RGB delay and output volume level settings
and allows you to change them.

Update firmware —

Allows you to replace the firmware that is coded on the

switcher’s control board without taking the switcher out of service,
opening the switcher enclosure, and replacing the firmware chip set.
See Updating the firmware on page 4-14.

Name presets —

Allows you to name each of the 16 memory presets.

Show RS-232 strings —

Displays the ASCII commands that are used by the

current configuration. You can refer to these for RS-232 programming.

Initialize —

Initializes and clears any or all of the following: ties, presets, RGB

delay, audio configuration, preset titles, icon names, and icons.

Audio-input Configuration selection —

Displays the Configure Audio Options

window (figure 4-12), which shows the audio gain level settings for each
input and allows you to change them.

Preferences menu —

Immediate changes —

Causes changes to take effect

immediately.

Hold/verify changes —

Delays implementation of

changes until the Changes – Take button is pressed.

Ties as lines —

Displays ties as lines (figure 4-13).

Figure 4-13 — Ties shown as lines