WLCA/WLHA High Wall Evaporator
WLCA/WLHA systEm options
notE:
Due to EMI’s ongoing development programs, design and specifications
may change without notice.
S1CA/S1HA
Side Discharge
WLCA/WLHA
S2CA
Side Discharge
CooLinG systEms WitH WALL Units
Condenser
Wall Unit
Btuh
sEEr sHr
EEr
ref.
S1CA9
WLHA09
9,000
13.0
.79
11.8
R22
S1CA2
WLHA12
12,000
13.0
.74
12.9
R22
S1CA8
WLHA24
18,000
13.0
.78
13.0
R22
S1CA4
WLHA24
24,000
13.0
.70
12.5
R22
S1CA3
WLCA36
30,000
13.0
.72
12.6
R22
S1CA6
WLCA36
33,600
13.0
.69
12.1
R22
HEAt pUmps systEm options WitH WALL Units
Condenser Wall Unit
Cooling
Btuh
Heating
Btuh
sEEr Hspf
sHr
EEr
Cop
ref.
S1HA9
WLHA09
9,000
8,200
13.0
7.7
.75
12.0
3.6
R22
S1HA2
WLHA12
12,000
10,200
13.0
7.7
.73
11.1
3.4
R22
S1HA8
WLHA24
18,000
16,400
13.0
7.7
.73
12.1
3.8
R22
S1HA4
WLHA24
23,000
20,600
13.0
7.7
.71
11.9
3.5
R22
CooLinG systEms WitH s2CA sidE disCHArGE
Wall Unit (s)
Condenser
Btuh
sEEr
sHr
EEr
ref.
WLHA09
S2CA99
18,000
13
.80
11.9
R22
WLHA12
S2CA22
23,000
13
.72
12.4
R22
WLHA09+WLHA12
S2CA92
21,000
13
.72
12.0
R22