beautypg.com

EMI WLHA User Manual

Page 22

background image

www.enviromaster.com

WLCA/WLHA High Wall Evaporator

22

sleep timer

The

SLEEP TIMER feature allows the

user, with the push of a single button, to

have the unit switch off using the preset tim-

er. When the control is in the “On” mode,

pressing the “TIMER” will enter or exit the

Sleep Timer mode. When in Sleep Timer

mode, the word “TIMER” will appear on the

LCD display. The unit will continue to oper-

ate for thirty (30) minutes then switch off.

test mode

Test mode is a feature where by all
timers are reduced or eliminated. Test
mode is intended to aid the technician

while checking system operation after in-

stallation or during trouble shooting. Test

mode is not intended for the end user or

for normal operation. Also test mode is
not available while in Remote Wall Ther-

mostat mode”.

To enter Test mode the control must

first be in the Off mode. Then by press-

ing the “ON/OFF”, “PROG” and “TIME”

buttons simultaneously for three seconds
the unit will enter the Test mode. While in

Test mode the display will flash “tSt” pe-

riodically. The operation of the unit can

be checked without having to wait out the

delays. To exit the Test mode press the

“ON/OFF”, “PROG” and “TIME” buttons

simultaneously again or by cycling off the

main power to the control.

CAUtion:

Do not cycle the unit

on and off repeatedly while in Test

mode as this will cause damage to

the compressor. Do not leave the

unit in Test mode

sEqUEnCE of opErAtion – Unit moUntEd KEy pAd modE

sEqUEnCE of opErAtion – WALL moUntEd tHErmostAt modE

For Wall mounted thermostat op-

eration the control must be configured

through the Configuration mode. Be sure

to select Remote – ON in the configura-

tion menu. (See Configuration mode)

In Remote Thermostat mode the unit

mounted keypad will have limited capabil-

ity. Some of the buttons will not be oper-

able. Only the FAN and TIME buttons will

function. The ability to clear the FILTER

CHECK warning will also be available by

pressing the MODE and FAN buttons si-

multaneously.

Choosing a Thermostat:

EMI offers several remote thermostats

that are compatible with the Ductless split

system air handlers. See the latest price

list for a list of available thermostats. It is

important to choose a thermostat that will

match the equipment that you have se-

lected. For single stage cooling or heart-

ing choose a single stage Heat/Cool ther-

mostat. If you have selected an outdoor

heat pump unit and an indoor unit with

electric heat then chose a two-stage heat-

ing, single-stage cooling thermostat.

Selecting a thermostat “by others”

When selecting a thermostat other than

those offered by EMI, it is important to

choose a 24V thermostat that matches

your application. EMI equipment is com-

patible with most mercury bulb, digital or

power steeling thermostats.

Cooling Only:

Select a thermostat that is compatible

with a cooling system. The thermostat

should have “R”, “Y” and “G” terminals

and may also have a “C” terminal.

Cooling only with Electric Heat:

Select a thermostat that is compatible

with a cooling - electric heat system. The

thermostat should have “R”, “Y”, “W” and

“G” terminals. The thermostat may also

have a “C” terminal.

This manual is related to the following products: