beautypg.com

Starting warm engine, Stopping engine – Echo PB-250 User Manual

Page 13

background image

13

P

ower

B

lower

o

Perator

'

s

M

anual

sTarTIng

warm

engIne

The starting procedure is the same as Cold Start except DO NOT close

the choke.

1. Stop Switch

Move stop switch button (A) away from the STOP position.

2. Throttle

Position

Lever

Move throttle position lever (B) midway between idle and full

throttle positions.

3. Purge Bulb

Pump purge bulb (D) until fuel is visible and flows freely in the

clear fuel tank return line.

4. Recoil

Starter

Place the unit on a flat, clear area. Firmly grasp throttle grip with

left hand and rapidly pull recoil starter handle/rope (E) until en-

gine fires.

IMPORTANT

Recoil starter: Use short pulls - only 1/2 ~ 2/3 of rope for start-

ing. Do not allow the rope to snap back in. Always hold the unit

firmly.

NOTE

If engine does not start after 5 pulls, use Cold Start Procedure.

sToppIng

engIne

1. Throttle Trigger/Throttle Position Lever

Release throttle trigger (F). Move throttle position lever (B)

forward to idle position and allow engine to return to idle before

shutting off engine.

2. Stop Switch

Move stop switch (A) to “STOP” position.

warning

If engine does not stop when stop switch is moved to STOP posi-

tion, close choke - COLD START ( ) position - to stall engine.

Have your ECHO dealer repair stop switch before using blower

again.

F

B

a

B

a

E

D D