Type of gas – Electrolux 34942G User Manual
Page 13
13
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Triple-Crown
56
Aeration adjustment none
BURNER
R A P I D
SEMI-RAPID
A U X I L I A R Y
T R I P L E
( l a r g e )
( m e d i u m )
( s m a l l )
C R O W N
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER (kW)
3.0
0.65
2.0
0.45
1.0
0.33
4.0
1.2
NOMINAL FLOW
RATE (m
3
/h)
0.286 0.057
0.190
0.038
0.095 0.028
0.381 0.114
NOZZLE
REFERENCE
119 Adjust.
9 6
Adjust.
7 0
Adjust.
146 Adjust.
(1/100 mm)
NOMINAL THERMAL
POWER (kW)
2.8
0.65
2.0
0.45
1.0
0.33
4.0
1.2
NOMINAL FLOW
RATE (g/h)
202
43.5
144
2 9
7 2
21,5
252
8 6
NOZZLE REFERENCE
8 6
4 0
7 1
3 2
5 0
2 8
9 8
5 6
(1/100 mm)
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Instructions for the Installer