Specifi cations
Product type
TTL automatically controllable fl ash
Maximum guide
number
Approx. 42 (fi ring angle of 75 mm / standard light
distribution, ISO 100•m)
Firing angle
Auto/Manual
Focal length: 12 mm to 75 mm (35 mm-equivalent focal
length: 24 mm to 150 mm) / 7 mm (35 mm-equivalent focal
length: 14 mm) when using the built-in wide panel
Light distribution modes: Standard / Wide*
* The same light distribution as the standard mode when the fi ring
angle is 12 mm or less.
Flash control modes
TTL / MANUAL / FP TTL / FP MANUAL / MULTI
Flash compensation
±5 EV (Increment: 1/3 EV or 1/2 EV)
Manual fl ash intensity
From 1/1 to 1/128 (Increment: 1/3 EV or 1/2 EV)
Flash duration
From approx. 1/20000 second (M 1/128) to 1/950 second
(M 1/1)
Firing frequency*
1
Approx. 2.5 seconds (when using AA dry-cell alkaline
batteries) / Approx. 1.5 seconds (when using AA NiMH
batteries)
Number of fi rings*
1
Approx. 240 times (when using AA dry-cell alkaline batteries)
/ Approx. 280 times (when using AA NiMH batteries)
Bounce
Upward: 0° straight ahead; from 0° to 90° upward
To the left/right: 0° straight ahead; from 0° to 180° left/right
with lock mechanism
Built-in functions
Wide panel, catch light plate
Radio wireless function
Control modes
Commander: Commander / Commander fl ash
Receiver: RCV (commander fl ash control) / X-RCV (receiver
fl ash control)
Maximum
communication
distance*
1
Approx. 30 m (98.4 ft.)
Frequency
2.4 GHz band
Number of
channels
15 (in the commander mode; with automatic channel setting
function)
Number of groups
3; maximum number of units: unlimited
Flash control modes TTL / MANUAL / FP TTL / FP MANUAL / Off